Amplivox Model 270+ Advanced diagnostic audiometer atau Portable Audiometer 270 Amplivox merupakan atau ukur kemampuan pendengaran telinga manusia, Alat mengeluarkan bunyi yang dihubungkan dengan earphone yang dipakai oleh pasien dan meminta pasien memberikan respon ketika mendengarkan suara, Jual Portable Audiometer type 270 Amplivox - UK
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
Advanced diagnostic audiometer
Model : 270+ (Amplivox)
Specification :
| ▪ | Frequency range | ||
| Air Conduction range | : | 0.125, 0.25, 0.5, 0.75, 1.15, 2, 3, 4, 6, 8 kHz | |
| Bone Conduction | : | 0.25, 0.5, 0.75, 1.15, 2, 3, 4, 6, 8 | |
| Frequency accuracy | : | <1% | |
| Distortion | : | <2% | |
| Test method | : | Manual or automatic mode AC and BC | |
| Tone present | : | Continuous or interupted pulsed, warble | |
| ▪ | Output level range | ||
| Air Conduction range | : | -10 dBHL to 120 dBHL ±3dB | |
| Bone Conduction | : | -10 dBHL to 120 dBHL ±3dB | |
| Output level step | : | 1, 2, 5 dB | |
| ▪ | Masking | ||
| Masking | : | Norrowband and speech weighted noise | |
| Output | : | Headphones, insert earphone or insert masker | |
| Insert masking output | : | 90dBHL max (250-4 kHz) | |
| ▪ | Freefield | ||
| Output level range (FF) | : | Up to 90 dB | |
| No of loudspeaker | : | 2 | |
| ▪ | Special tests | ||
| Overthreshold tests | : | Stenger test, ABLB (Fowler), SISI, Tone decay (Cahart) |
|
| Simulators | : | MHA, HLS | |
| ▪ | Communication | ||
| Talk over | : | Integrated or external monitor headset | |
| Talk back | : | External microphone | |
| ▪ | Data management | ||
| Internal database | : | 10 audiograms | |
| Optional printer | : | MPT-II thermal printer | |
| Data transfer | : | Via USB to Amplisuite, NOAH, | |
| OtoAccess® and other EMR system | |||
| Languages | : | English, German, Polish | |
| ▪ | Speech Input | : | PC, tape, CD or MP3 input or live speech |
| ▪ | Safety and standard | ||
| Type | : | Audiometer Type 3BE/Type 2 | |
| Safety | : | IEC 60601-1 (plus UL, CSA & EN deviation | |
| EMC | : | IEC 60601-1-2 | |
| Performance | : | IEC 60645-1/ANSI S3.6 | |
| CE Mark | : | Complies to EU Medical Device | |
| Regulation (MDR 2017/745) | |||
| ▪ | Physical data | ||
| Display | : | 2 lines of 24 characters | |
| Power | : | 100-240Vac 50-60Hz | |
| Dimensions/weight | : | (L x W x H): 259 x 374 x 90mm / 1400 g | |
| ▪ | Complete unit | : | Main unit + Audiocups |
| : | Standard audiometric headset | ||
| : | Bone conduction headset | ||
| : | Patient response switch | ||
| : | Audiogram cards (50) | ||
| : | Mains power adaptor | ||
| : | Carry case | ||
| : | USB cable (PC connection) | ||
| : | Amplisuite PC software and NOAH connection module |